Answer: A pressure switch failure or drift or jam of the pressure switch setting value will prevent the air compressor from unloading in time when the set pressure limit is reached, causing the air compressor to continue to load and operate at a pressure exceeding the rated working pressure, causing the motor to overcurrent.